We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.

Professional Medical Equipment Supplier - Yuesen Med Professional Medical Equipment Supplier - Yuesen Med

Hot Products

YSX500D 50kW DR system set up and put into service in Cambodia.

YSENMED YSX500D 50kW digital x-ray system has been successfully set up and put into service in a hospital in Cambodia.

YSX056-PE serving as a vehicle-mounted x-ray in the Philippines

YSX056-PE 5.6kW portable x-ray unit has been adapted to fit on a truck, to provide mobile x-ray examination service for remote communities in the Philippines.

X Ray Machine  To  Zimbabwe

x ray machine, 50KW x ray machine

Microscope To Malawi

Achromatic objectives: 4X、10X、40X(S), 100X(S、Oil) Wide field eyepiece: WF10X(WF16X for option) Eyepiece head: Sliding binocular head inclined at 45° Stage: Double layer mechanical stage size 140X140mm, moving range 75X45mm Focusing: Coaxial coarse and

ECG

Views : 1390
Author : Sophie Lin
Update time : 2015-12-25 08:00:00
Automatic Recording  ECG is convenient and practical for doctores operation. Therefore, it is very important for wide application.
 
a. Power on the ECG by turning the AC switch to “I”and continuous pressing key “ON/OFF” until the unit displays initial operation conditions.
 
b. Press key “MODE” to select automatic recording mode of which a prompt “AUTO” will be displayed on the LCD. At the moment, you can check the displayed ECG trace of each lead by one after another for stability by ways of keys “<” and “>”. If necessary, you can press key of the ECG from Chinese medical equipment manufacturer“RESET” to guarantee a stable ECG trace.
 
c. Press key “START/STOP” to start recording of ECG trace. Upon the end of each recording, the unit will carry out automatically measurement and interpretation on the ECG trace as well as print out the related report before stopping operation.
 
Upon receiving effective code number of the ECG from Chinese medical equipment manufacturer, the computer then check the localized memory to validate the stored ECG trace & data and display them on the LCD. If they are invalid, the unit exit the current status and return to the same status as recording is stopped.
Related News
Read More >>
What is the Digital Radiography System? What is the Digital Radiography System?
Nov .09.2025
In this article, we'll dive deep into the world of digital radiography, exploring its components, advantages, and applications.
How Do Surgical Lights Have No Shadows? How Do Surgical Lights Have No Shadows?
Oct .29.2025
In this article, we'll dive deep into the science behind surgical lighting, explore its design, and understand why it's crucial for successful surgeries.
Which is Better, an Oxygen Concentrator or a Ventilator? Which is Better, an Oxygen Concentrator or a Ventilator?
Oct .26.2025
When it comes to respiratory support, two terms often pop up: oxygen concentrators and ventilators. But what do these devices do, and which one is better for your needs?
Day 3 at WHX Nairobi 2025 (Medic East Africa) Day 3 at WHX Nairobi 2025 (Medic East Africa)
Oct .25.2025
It's the final day here at the WHX Nairobi 2025.

We have spent 3 happy & fruitful days with many medical professionals and distributors from across the Kenya and neighbouring countries.