Portable multi-parameter patient monitor
Item No.: YSF8-s
12.1 Inch Portable Multi-parameter Patient Monitor YSF8-s
Description
12.1 Inch Portable Multi-parameter Patient Monitor YSF8-s Good Price

YSF8-s Features
• 12.1'color TFT LCD screen
• Acoustic and visual alarm
• Display mode: Standard, Large Font, NIBP Trend, Trend Table, Full lead ECG, Oxy CRG
• Drug calculation and titration table
• Real time ST segment analysis, pacemaker detection and Arrhythmia analysis
• Suitable for monitoring adult, pediatric and neonatal patient
• Supporting storage of 240 hours patient data, 1024 NIBP records and 1024 alarm event
• Isolated against defibrillation effect
YSF8-s Standard Configuration:
• 3-lead or 5-lead ECG/HR, RESP, Dual TEMP, SpO2/PR, NIBP
YSF8-s Optional Configuration:
• Touch screen, Printer, Trolley, Wall-mount
Configuration


YSF8-s Features
• 12.1'color TFT LCD screen
• Acoustic and visual alarm
• Display mode: Standard, Large Font, NIBP Trend, Trend Table, Full lead ECG, Oxy CRG
• Drug calculation and titration table
• Real time ST segment analysis, pacemaker detection and Arrhythmia analysis
• Suitable for monitoring adult, pediatric and neonatal patient
• Supporting storage of 240 hours patient data, 1024 NIBP records and 1024 alarm event
• Isolated against defibrillation effect
YSF8-s Standard Configuration:
• 3-lead or 5-lead ECG/HR, RESP, Dual TEMP, SpO2/PR, NIBP
YSF8-s Optional Configuration:
• Touch screen, Printer, Trolley, Wall-mount
| Physical Specifications | ||
| Dimension and weight | Dimension | 375mm(W)*330mm(H)*180mm(D) |
| Weight | standard configuration: 4.4 kg | |
| Operation environment | Power requirements | AC 90-300V, 50/60HZ, 60W |
| Power | 90VA | |
| Temperature | 0-40℃ | |
| Humidity | 0-93% non-condensing | |
| Safety | Meet the requirements of IEC60601 series | |
| Patient range | Adult, neonate and pediatric patients | |
| Performance Specification | ||
| Display | 12.1 inch (800 x 600 pixel) color TFT LCD rolling and refreshing waveform display | |
| Display mode | Standard, large font, trend table, full lead ECG, Oxy CRG,NIBP trend | |
| Interface |
Parameter cable interface AC power input socket |
|
| Battery | Rechargeable battery, 2.2 Ah 12V | |
| Alarm indicator | Visual on-display and integrated alarm light Audible alarm and personated voice reminding alarm |
|
| Data storage |
240 hours monitoring data 1024 NIBP records storage 1024 alarm event |
|
| Printer |
Built-in 50mm thermal printer (option), 2 traces, print speed 25mm/s & 50mm/s print width:50mm |
|
| ECG | ||
| Leads type | 3(option)/5-lead : I, II, III, aVR, aVL, aVF, V | |
| Sweep speed | 12.5mm/s, 25mm/s 50mm/s | |
| Gain selection | ×0.25, ×0.5, ×1, ×2 | |
| ECG waveform | 1 channels | |
| Operation mode | Diagnostic, monitor, surgery | |
| Heart rate range | 0 -300bpm | |
| Accuracy | 1bpm or ±1% whichever is great | |
| Alarm range | Audible and visual alarm, adjustable | |
| ST/ arrhythmia | Real time S-T segment detection, pace detection and arrhythmia analysis | |
| Protection | Against electrosurgical interference and defibrillation | |
| Respiration (RESP) | ||
| Method | Thoracic impedance | |
| Operation mode | Auto | |
| Measurement range | Adult: 0-120BrPM; neonatal /pediatric: 0-150BrPM | |
| Apnea alarm | Yes | |
| Alarm | Yes, audible and visual alarm ,alarm events recallable | |
| NIBP | ||
| Method | Automatic oscillometric | |
| Operation mode | Manual/Automatic/STAT | |
Configuration
| Auto measure time | Adjustable | |
| Measurement unit | mmHg / kPa selectable | |
| Test interval | 1-480 minutes | |
| Measurement range |
Adult: 0-300 mmHg ; Child: 0-240 mmHg ; Infant: 0-150 mmHg |
|
| Over-pressure protection | Double safety protection | |
| Accuracy of blood pressure measurement | The mean error shall be less than±5mmHg the standard deviation shall be less than 8mmHG |
|
| Resolution | 1 mmHg | |
| SPO2 | ||
| Measurement range | 0%-100% | |
| Resolution | 1% | |
| Accuracy | ±2% (70-100%, adult/pediatric, non-motion ) ±3% (70-100%, neonate, non-motion ) ±3% (70-100%, adult/pediatric/neonate, motion ) 0-69% unspecified |
|
| Alarm range | 1-100% | |
| Pulse rate | Pulse range: | 20-300bpm |
| Accuracy: | ±3bpm(non-motion) ±5bpm(motion ) |
|
| Temperature (TEMP) | ||
| TEMP range | 0-50℃ | |
| Resolution | 0.1 ℃ | |
| Accuracy | ±0.1℃ (excluding the sensor) | |
| Channel | Single channel. | |