Hot Products
Veterinary Anesthesia Machine YSAV710C Plus Vet
Item No.: YSAV710C Plus Vet
Versatile anesthesia machine with integrated ventilator, 10.2" touchscreen, multi-mode ventilation, precision flow meter, and dual-bellow setup. Reliable, safe, and customizable.
| Product parameters | |
| Brand: | YSENMED |
| MOQ: | 1 |
| Package: | Wooden Package |
| Ship From: | Guangzhou |
| Lead Time: | 3-15 days |
| Customization: | Customized package |
Description
Anesthesia Machine
Gas Supply:
Gas Source: O2,or O2&Air(Option);
Gas Source Pressure Gauge: O2,or O2&Air(Option);
Pressure of Pipeline inlet:
O2,280kPa~600kPa/41Psi~87Psi, less than 180L/min;
Air(Option),280kPa~600kPa/41Psi~87Psi, less than 180L/min;
Security Valve: release pressure less than 10 kpa;
O2 Lost Alarm(Option):Sound alarm, aluminum cylinder with whistle;
Flow Meter:
2 tubes high precision flow meter,0~1L/min,1.1L/min~10L/min; or 0L/min~10L/min(O2&Air);
Precision: At 20 degree, atmospheric pressure is 101.3kPa, the precision of flow meter is level:2.5;
O2 Flush: 35L/min~75L/min;
One Key Switch: Switch between rebreath and Non-Rebreath;
ACGO Port: Non-Rebreath;
Selectatec Mounting Bar: single place used for vaporizer, it is easy to replace;
Vaporizer;
Anesthesia Vaporizer: one of Isoflurane/Halothane/Sevoflurane;
Respiration System/CO2 Circle Absorber/Rebreath:
Soda Lime Chamber: 800ml;
Pop Off Valve: with one key to close; APL valve(Option): 0.19~6kPa;
Airway Pressure Gauge:-20-100cmH2O;
Anesthesia Ventilator
Drive gas: O2 or Air, Inlet pressure: 280-600 kPa. Max flow≤ 120 L / min;
Safety Pressure: System pressure does not exceed 10 KPa;
Display:10.2" TFT, with touch screen;
Breath Mode:VS,VCV,PCV, SIMV-VC, SIMV-PC, PSV,PRVC, SIMV-PRVC, Manual/SPONT;
Waveform:Pressure,Flow rate,Volume, Loop,PV loop, PF loop,FV loop
O2 concentration Monitor:15%-100%(option);
Electric PEEP: OFF, 3 ~ 30 cmH2O;
Battery Type:Li-ion,work time more than 3 hours;
Parameters setting range:
Tidal volume:10 - 1500ml;
Respiratory rate:1 ~ 100 bpm;
Inspiratory time:0.1~10.0s; Respiratory rate:0 ~ 100 bpm;
Percentage of inspiratory pause:0 to 60%;
PEEP:OFF, 3 ~ 30 cmH2O;
Pressure Support:0 ~ 70 cmH2O;
Pressure Control:5 ~ 70 cmH2O;
Flow trigger:0.5 ~ 20L/min;
Pressure Trigger:0 ~ 20 cmH2O;
PSV Insp Termination Level:5 ~ 80%;
Monitored parameters:
Inspiratory tidal volume: 0 ~ 3000 mL;
Expiratory tidal volume:0 ~ 3000 mL;
Spontaneous minute ventilation:0 ~ 60 L / min;
Minute ventilation:0 ~ 60 L / min;
Respiratory ratio:4:1 to 1:10;
Spontaneous breathing frequency:0 ~ 100 bpm;
Compliance:0 ~ 300 mL/cmH2O;
Respiratory ratio:30:1 to 1:150;
Peak airway pressure:0 ~ 100 cmH2O;
Mean airway pressure:0 ~ 100 cmH2O;
PEEP:0 ~ 100 cmH2O;
Inspiratory plateau pressure:0 ~ 100 cmH2O;
FiO2(option):15 to 100%;
EtCo2,FiCO2(option);
EtCO2, FiCO2, EtN2O, FiN2O, FiO2, EtO2, EtAA, FiAA, MAC(option);
Alarm settings:
Tidal volume high/low alarm; Minute ventilation high/low alarm; Respiratory rate high/low alarm; Airway pressure high/low alarm; Continuous Positive Airway Pressure/Negative pressure alarm; Apnea alarm; Oxygen deficiency alarm; AC power failure alarm ,Low battery alarm.
Standard configuration:
Anesthesia machine with anesthesia ventilator, one unit X60 Anesthesia vaporizer, one unit big bellow, one unit small bellow, one set big disposable breath circuit, one set small disposable breath circuit, one set open breath circuit, 0.5,1.2,3L airbag, O2 gas source pipeline.
Option: O2 Concentration Monitor, EtCo2, AG;
Packing Information:
Main unit:93cm*31cm*75cm,gross weight 32kg;
Anesthesia vaporizer:33cm*22cm*33cm,gross weight 7.5kg;
Trolley:68cm*58cm*28cm,gross weight 12kg;







Gas Supply:
Gas Source: O2,or O2&Air(Option);
Gas Source Pressure Gauge: O2,or O2&Air(Option);
Pressure of Pipeline inlet:
O2,280kPa~600kPa/41Psi~87Psi, less than 180L/min;
Air(Option),280kPa~600kPa/41Psi~87Psi, less than 180L/min;
Security Valve: release pressure less than 10 kpa;
O2 Lost Alarm(Option):Sound alarm, aluminum cylinder with whistle;
Flow Meter:
2 tubes high precision flow meter,0~1L/min,1.1L/min~10L/min; or 0L/min~10L/min(O2&Air);
Precision: At 20 degree, atmospheric pressure is 101.3kPa, the precision of flow meter is level:2.5;
O2 Flush: 35L/min~75L/min;
One Key Switch: Switch between rebreath and Non-Rebreath;
ACGO Port: Non-Rebreath;
Selectatec Mounting Bar: single place used for vaporizer, it is easy to replace;
Vaporizer;
Anesthesia Vaporizer: one of Isoflurane/Halothane/Sevoflurane;
Respiration System/CO2 Circle Absorber/Rebreath:
Soda Lime Chamber: 800ml;
Pop Off Valve: with one key to close; APL valve(Option): 0.19~6kPa;
Airway Pressure Gauge:-20-100cmH2O;
Anesthesia Ventilator
Drive gas: O2 or Air, Inlet pressure: 280-600 kPa. Max flow≤ 120 L / min;
Safety Pressure: System pressure does not exceed 10 KPa;
Display:10.2" TFT, with touch screen;
Breath Mode:VS,VCV,PCV, SIMV-VC, SIMV-PC, PSV,PRVC, SIMV-PRVC, Manual/SPONT;
Waveform:Pressure,Flow rate,Volume, Loop,PV loop, PF loop,FV loop
O2 concentration Monitor:15%-100%(option);
Electric PEEP: OFF, 3 ~ 30 cmH2O;
Battery Type:Li-ion,work time more than 3 hours;
Parameters setting range:
Tidal volume:10 - 1500ml;
Respiratory rate:1 ~ 100 bpm;
Inspiratory time:0.1~10.0s; Respiratory rate:0 ~ 100 bpm;
Percentage of inspiratory pause:0 to 60%;
PEEP:OFF, 3 ~ 30 cmH2O;
Pressure Support:0 ~ 70 cmH2O;
Pressure Control:5 ~ 70 cmH2O;
Flow trigger:0.5 ~ 20L/min;
Pressure Trigger:0 ~ 20 cmH2O;
PSV Insp Termination Level:5 ~ 80%;
Monitored parameters:
Inspiratory tidal volume: 0 ~ 3000 mL;
Expiratory tidal volume:0 ~ 3000 mL;
Spontaneous minute ventilation:0 ~ 60 L / min;
Minute ventilation:0 ~ 60 L / min;
Respiratory ratio:4:1 to 1:10;
Spontaneous breathing frequency:0 ~ 100 bpm;
Compliance:0 ~ 300 mL/cmH2O;
Respiratory ratio:30:1 to 1:150;
Peak airway pressure:0 ~ 100 cmH2O;
Mean airway pressure:0 ~ 100 cmH2O;
PEEP:0 ~ 100 cmH2O;
Inspiratory plateau pressure:0 ~ 100 cmH2O;
FiO2(option):15 to 100%;
EtCo2,FiCO2(option);
EtCO2, FiCO2, EtN2O, FiN2O, FiO2, EtO2, EtAA, FiAA, MAC(option);
Alarm settings:
Tidal volume high/low alarm; Minute ventilation high/low alarm; Respiratory rate high/low alarm; Airway pressure high/low alarm; Continuous Positive Airway Pressure/Negative pressure alarm; Apnea alarm; Oxygen deficiency alarm; AC power failure alarm ,Low battery alarm.
Standard configuration:
Anesthesia machine with anesthesia ventilator, one unit X60 Anesthesia vaporizer, one unit big bellow, one unit small bellow, one set big disposable breath circuit, one set small disposable breath circuit, one set open breath circuit, 0.5,1.2,3L airbag, O2 gas source pipeline.
Option: O2 Concentration Monitor, EtCo2, AG;
Packing Information:
Main unit:93cm*31cm*75cm,gross weight 32kg;
Anesthesia vaporizer:33cm*22cm*33cm,gross weight 7.5kg;
Trolley:68cm*58cm*28cm,gross weight 12kg;








YOUR MAY ALSO LIKE ...