YS-AED7000P AED Defibrillator With LCD Display
Item No.: YS-AED7000P
| Product parameters | |
| Brand: | Yesenmed |
| MOQ: | 1 |
| Package: | Carton |
| Ship From: | Guangzhou |
| Lead Time: | 3-5 days |
| Customization: | Customized package |
Description
YS-AED7000P AED Defibrillator With LCD Display




Features
1.three-step defibrillation process
2.two-button operation
3.extensive voice and visual prompts for the operator
4.biphasic energy output
5.3.5 inch LCD display
Specification
Standard: 1 battery + 1 pair of adult electrodes + 1 bag




1.three-step defibrillation process
2.two-button operation
3.extensive voice and visual prompts for the operator
4.biphasic energy output
5.3.5 inch LCD display
Specification
| Category | Specification |
| Output | Biphasic Truncated exponential |
| Energy Sequence(adult ) | 150/150/200(Default) 150/200/200 200/200/200 Note: the Energy sequence can be changed using the computer IR port. |
| Analysis Time | 9 sec. |
| Energy Sequence(Pediatric) | 50/70/85(Default) 70/70/85 70/85/85 85/85/85 Note: the Energy sequence can be changed using the computer IR port. |
| Charge Time | 10 sec. to 200 J |
| The maximum time from the initiation of rhythm analysis to readiness for maximum Energy discharge after 15 shocks. | Less than 20 seconds |
| The maximum time from initially switching power on to readiness for maximum Energy discharge after 15 shocks.. | Less than 30 seconds |
| Audible Prompts | 19 audible prompts |
| Visual Prompts | LED prompts; Automatic self-test |
| Controls | six buttons - On/Off, Shock, and 4 software-configurable buttons |
| Output Energy Accuracy | ±15% into any impedance from 25 to 175Ω |
| The Maximum Voltage | 1800±20V |
| Output disabled when the PATIENT impedance is outside limits | 20Ω to 200Ω |
| Recovery of the ECG input after defibrillation | <10s |
Standard: 1 battery + 1 pair of adult electrodes + 1 bag